Example S.M.A.R.T Output

smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Model Family:     Western Digital Caviar Second Generation Serial ATA family
Device Model:     WDC WD3200KS-00PFB0
Serial Number:    WD-WCAPD2893694
Firmware Version: 21.00M21
User Capacity:    320,072,933,376 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   7
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Wed Mar 12 13:14:33 2008 MDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x84) Offline data collection activity
                                        was suspended by an interrupting command from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (9600) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 111) minutes.
Conveyance self-test routine
recommended polling time:        (   6) minutes.
SCT capabilities:              (0x103f) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_
FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   200   200   051    Pre-fail  Always       -
       0
  3 Spin_Up_Time            0x0003   187   187   021    Pre-fail  Always       -
       5608
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -
       351
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -
       0
  7 Seek_Error_Rate         0x000f   200   200   051    Pre-fail  Always       -
       0
  9 Power_On_Hours          0x0032   098   098   000    Old_age   Always       -
       2174
 10 Spin_Retry_Count        0x0013   100   100   051    Pre-fail  Always       -
       0
 11 Calibration_Retry_Count 0x0013   100   100   051    Pre-fail  Always       -
       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -
       350
190 Airflow_Temperature_Cel 0x0022   065   047   000    Old_age   Always       -
       35
194 Temperature_Celsius     0x0022   115   097   000    Old_age   Always       -
       35
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -
       0
197 Current_Pending_Sector  0x0012   200   200   000    Old_age   Always       -
       0
198 Offline_Uncorrectable   0x0010   200   200   000    Old_age   Offline      -
       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -
       0
200 Multi_Zone_Error_Rate   0x0009   200   200   051    Pre-fail  Offline      -
       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.