Crash Recovery Kit for Linux 2.6.11.10 (i586)
with S.M.A.R.T. monitoring support using smartmontools 5.33 
which also can monitor SATA drives using kernel 2.6.11.10.

See also freshmeat : http://freshmeat.net/releases/196542/

Download is at :
http://crashrecovery.org/CrashRecoveryKit/iso/2.6.11.10/
ftp://ftp.crashrecovery.org/pub/linux/CrashRecoveryKit/is...

HOWTO is at :
http://crashrecovery.org/CrashRecoveryKit/iso/2.6.11.10/H...

Homepage is at : http://crashrecovery.org/

Here's what my Seagate 200Gb SATA drive reports :

		S.M.A.R.T. the smartmontools have been added. The kernel
		has been patched with the 2.6.11-libata-dev1.patch.bz2
		by Jeff Garzik which also makes S.M.A.R.T. monitoring of
		SATA drives possible:

		# smartctl -a -d ata /dev/sdd
smartctl version 5.33 [i586-mandrake-linux-gnu] Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     ST3200822AS
Serial Number:    3LJ1P6WG
Firmware Version: 3.01
User Capacity:    200,049,647,616 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   6
ATA Standard is:  ATA/ATAPI-6 T13 1410D revision 2
Local Time is:    Wed May 18 17:25:00 2005 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		 ( 430) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					No General Purpose Logging support.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 111) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   056   051   006    Pre-fail  Always       -       113663975
  3 Spin_Up_Time            0x0003   096   096   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       29
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   085   060   030    Pre-fail  Always       -       352649124
  9 Power_On_Hours          0x0032   094   094   000    Old_age   Always       -       5923
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       33
194 Temperature_Celsius     0x0022   030   048   000    Old_age   Always       -       30
195 Hardware_ECC_Recovered  0x001a   056   049   000    Old_age   Always       -       113663975
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   199   000    Old_age   Always       -       1
200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age   Offline      -       0
202 TA_Increase_Count       0x0032   100   253   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%      5892         -
# 2  Short offline       Completed without error       00%      5892         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.